Installation Of The Acorn 120 Superglide Stairlift In 4 Easy Steps!
The Rail Assembly The Carriage Assembly The Seat Assembly Post Installation Checks
      Step 4

Post Installation Checks

1. Footrest ‘up’ safety circuit operative - with the lift ascending, push up-side spring-loaded edge of footrest - lift should stop immediately.
2. Footrest ‘down’ safety circuit operative - with the lift descending, push down-side spring-loaded edge of footrest - lift should stop immediately.
3. Footrest base safety circuit operative - with the lift descending, push the base of the footrest upwards - lift should stop immediately.
4. Carriage‘up’ safety circuit operative - with the lift ascending, push the up-side spring-loaded moulding attached to the carriage, immediately surrounding the rail - lift should stop immediately.
5. Carriage ‘down’ safety circuit operative - with the lift descending, push the down-side spring-loaded moulding attached to the carriage immediately above the rail - lift should stop immediately.
6. Bottom stopping limit operative - run the lift right to the bottom of the rail - lift should automatically come to a ‘soft’ stop at the foot of the staircase.
7. Top stopping limit operative - run the lift right to the top of the rail - lift should automatically come to a ‘soft’ stop at the top of the staircase.
8. Remote controls operative - pressing the red button causes the lift to ascend after a 3 second delay - pressing the green button causes the lift to descend after a 3 second delay.
9. Key ‘off’ LED warning - with the key in the ‘stop’ position, the red LED is illuminated and the lift will not operate.
10. Seat swivel LED warning - with the seat swivel mechanism not locked in the riding position (i.e. facing up the staircase) the yellow LED is illuminated and the lift will not operate.
11. Lift ‘off-charge’ audible warning - with the lift stopped in mid-travel, (i.e. off the upper or lower charge points) a 40 second pause is followed by the red, yellow and green LEDs flashing for 40 seconds accompanied by an audible warning (continuous ‘bleeping’) for a further 40 seconds, followed by restoration of a steady green LED - the lift will operate as normal if activated by the toggle switch or remote controls.

Still having problems?

Check the self diagnostic lights, to find the problem and evaluate the corrective action.

 