Post Installation Checks
|
| 1. |
Footrest ‘up’ safety circuit operative - with the lift
ascending, push up-side spring-loaded edge of footrest - lift should
stop immediately. |
| 2. |
Footrest ‘down’ safety circuit operative - with the
lift descending, push down-side spring-loaded edge of footrest - lift
should stop immediately. |
| 3. |
Footrest base safety circuit
operative - with the lift descending, push the base of the footrest
upwards - lift should stop immediately. |
| 4. |
Carriage‘up’ safety circuit operative - with the lift
ascending, push the up-side spring-loaded moulding attached to the
carriage, immediately surrounding the rail - lift should stop
immediately. |
| 5. |
Carriage ‘down’ safety circuit operative - with the
lift descending, push the down-side spring-loaded moulding attached to
the carriage immediately above the rail - lift should stop immediately. |
| 6. |
Bottom stopping limit operative - run the lift right to
the bottom of the rail - lift should automatically come to a ‘soft’ stop
at the foot of the staircase. |
| 7. |
Top stopping limit operative - run the lift right to
the top of the rail - lift should automatically come to a ‘soft’ stop at
the top of the staircase. |
| 8. |
Remote controls operative - pressing the red button
causes the lift to ascend after a 3 second delay - pressing the green
button causes the lift to descend after a 3 second delay. |
| 9. |
Key ‘off’ LED warning - with the key in the ‘stop’
position, the red LED is illuminated and the lift will not operate. |
| 10. |
Seat swivel LED warning - with
the seat swivel mechanism not locked in the riding position (i.e. facing
up the staircase) the yellow LED is illuminated and the lift will not
operate. |
| 11. |
Lift ‘off-charge’ audible warning - with the lift
stopped in mid-travel, (i.e. off the upper or lower charge points) a 40
second pause is followed by the red, yellow and green LEDs flashing for
40 seconds accompanied by an audible warning (continuous ‘bleeping’) for
a further 40 seconds, followed by restoration of a steady green LED -
the lift will operate as normal if activated by the toggle switch or
remote controls. |
Still having problems?
Check the
self diagnostic lights,
to find the problem and evaluate the corrective action. |