Commercial Wheelchair Lift

Planet mobility wheelchair lifts allow people with mobility issues to remain active, improving the quality of life. It's there personal freedom, and that is important to us… That is our job.

Safety, comfort and convenience were Planet Mobility's  #1 design considerations.

Features

  • Innovative Soft Touch Control Pads for ease of operation.
  • Direct drive Worm-Gear / Screw-Nut Drive for maintenance free operation, incorporating zero load start for cold weather climates (drive system allows motor to get up to full speed before lifting car).
  • Expanded Metal Platform allows full under platform visibility.
  • Keyed Emergency Stop to control use of lift.

Smooth and quiet performance makes this light weight, dependable and versatile unit perfect for any residential or commercial application. 

Our High Tower Lift's will go as high as 12' Feet and can be used with many applications.
 
"Straight Trough": Straight through application means that the lift would be entered by one side and after raising and reaching the destination landing would be exited on the opposite side.
 
"Adjacent Access": Adjacent access application means that the lift would be entered by one side and after raising and reaching the destination landing would be exited to the right or left.
 
"Same Side": Same side application means that the lift would be entered by one side and after raising and reaching the destination landing would be exited at the same location it was entered.
 

Design Your Lift Here!

 

Technical Specifications

 
Adjacent Access
Straight Through Access

Deck Dimensions (L, D, W)

Access
L
Deck Length
D
Deck Width
W
Total Width
Straight Through Access
54" (1372 mm)
34" (864 mm)
48" (1219 mm)
Adjacent Access
54" (1372 mm)
40" (1016 mm)
54" (1372 mm)

Tower Dimensions (H)

Total Travel
H
Tower Height
28" (711 mm) Lift Height
48" (1219 mm)
52" (1321 mm) Lift Height
72" (1829 mm)
72" (1829 mm) Lift Height
92" (2337 mm)
96" (2438 mm) Lift Height
118" (2997 mm)
120" (3048 mm) Lift Height
142" (3607 mm)
144" (3658 mm) Lift Height
166" (4216 mm)


 


Technical

  • Constant pressure Soft Touch control pads
  • 550 pound (250-kg) lift capacity
  • Constant pressure Soft Touch control pads
  • 8 feet/minute lift speed
  • Direct worm gear/acme screw drive
  • Non-load-bearing backup safety nut on lift shaft
  • Low maintenance
  • Expanded metal platform with full under platform visibility and non skid surface
  • 8" positive action, reversible toe-plate for universal access
  • Emergency manual operation
  • Fuse box accessible from carriage
  • Quick and easy set-up and adjustment
  • Baked on Powder Coat finish
  • Baked on Powder Coat finish
  • Extreme Weather resistant design
  • U.L. and C.S.A. Certified

Options

  • Under platform safety plate and solid platform
  • Carriage gate
  • Landing gates
  • Portable model
  • Solid Hand Rail
  • 12V DC battery backup
  • 18" extra wide toe plate
  • Remote call stations
  • Electric Interlocks

 

View Drawing Spec Sheet #1

 

View Drawing Spec Sheet #2

 
--  
Commercial Trust-T-Lift Installation Instructions
 
The Commercial Trust-T-Lift is pre-assembled and tested in the factory before shipping. The lift is then disassembled into the components shown in Figure 1. All fasteners required to assemble the lift are re-installed in their respective positions after disassembly, except for the Lower Mechanical Stops (5/8" X 3" Carriage Bolts) included with the small parts bag.
Assembly of the Commercial unit is as follows:  

Straight or Adjacent Access Unit

  • Carefully unpackage the Commercial Trust-T-Lift components, confirm the following parts as shown in Fig. 1 are included:
  o Trust-T-Lift Tower Part A
o Carriage with Toe Plate Part B
o Base Frame Part C
o Solid Handrail Part D
o Control Wall Extension Part E
o Carriage Gate Part F
o Upper Gate Part G
o Lower Remote Call Station Part H
o Tower Mounting Angle Part I
FIG. 1- PARTS INCLUDED WITH A STRAIGHT COMMERCIAL UNIT Adjacent Unit will also include a corner post (not shown)



FIG. 2- PLUGGING IN UNDER DECK SAFETY LIMITS
  • Install the base frame, tower and carriage according to the Trust-T-Lift Installation Manual Pages 1-1 to 2-3, in order to operate the lift without field wiring completed, use a 12" insulated jumper wire and bypass from #1 to #5 for down movement and from #1 to #2 for up movement. Use extreme caution when running the unit down as the lower limit switch is bypassed and the drive nuts could possibly run out of the guide channel
  • Plug the Under Deck Safety Limits into the Inside Junction Box as shown in Fig. 2.
  • From this point forward in order to run the unit without the field wiring completed, only bypass #1 to #2 on the terminal strip (do not hardwire the jumper wire in place, only bypass when movement is required)
 
 
 


FIG. 3- REMOVE FRONT PANEL
  • Remove the front panel from the Trust-T-Lift Unit as shown in Fig. 3.



FIG. 4- INSTALLING LOWER MECHANICAL STOPS
  • Insert the (2X) 5/8"X3" Carriage Bolts and 5/8" Jam Nuts into the Lower Mechanical Stop brackets on the underside of the guide frame as shown in Fig. 4. Thread the bolts into the Mechanical stops about ½", they will be adjusted and jammed into place towards the end on the installation.



FIG. 5A- INSTALLING CONTROL WALL EXTENSION
  • Mount the Control Wall Extension to the Guide Frame as shown in Fig. 5A/5B.
  • Fasteners- (6X) 10/32 X ½" Flathead screws with (6X) Chrome Finishing Washers

FIG. 5B- FASTENING CONTROL WALL EXTENSION TO GUIDE FRAME
 
 
 
 


FIG. 6A- LOWER THE HANDRAIL INTO PLACE
  • For a Straight Access Unit Mount the Solid Handrail to the Carriage as shown in Fig. 6A/6B
  • Fasteners- (4X) 5/16 X 1¾" Bolts, (8X) 5/16 Washers, (4X) 5/16 Locknuts)
  • For an Adjacent Access Unit Mount the Solid Handrail to the Carriage as shown in Fig. 7A/7B, the safety pan must be lowered to access the mounting holes. After mounting the Solid Handrail attach it to the Control Wall Extension using small 1" Angle, remount safety pan to finish
  • Fasteners- (3X) 3/8 X 1¼" Bolts, (3X) 3/8" Locknuts, (2X) 10/32 X ½" Screws



FIG. 6B- BOLT HANDRAIL TO CARRIAGE



FIG. 7A- LOWER SAFTEY PAN TO ACCESS BOLT HOLES

FIG. 7B- BOLT HANDRAIL TO CARRIAGE
 
 
 
 


FIG. 8- MOUNTING GATE TO CONTROL WALL EXTENSION
  • Mount the Carriage Gate to the Control Wall Extension as shown in Fig. 8.
  • Fasteners- (8X) 12/24 X ½" Flathead Screws



FIG. 9- MOUNT CORNER POST FOR ADJACENT UNIT
  • On Adjacent Units mount the corner post as shown in Fig. 9. Square it to Carriage Gate, if necessary shim with washers provided



FIG. 10- RUN CABLE UNDER TOE PLATE
  • Run Interlock cable under the toe plate as in Fig. 10
 
 
 
 


FIG. 11- MOUNT INTERLOCK TO SOLID HANDRAIL
  • Mount the Carriage Gate Interlock to the Solid Hand Rail for a Straight Unit and to the Corner Post for an Adjacent Unit as shown in Fig. 11
  • Fasteners- (2X) 10/32 X 1½" Screws



FIG. 12- ADJUST INTERLOCK KEY TAB IF NECESSARY
  • Adjustment of the Interlock Key Tab may be necessary to allow proper alignment, loosen the (2X) 10/32 X ½" screws mounting it to the Aluminum Gate Tab and adjust as necessary as shown in Fig. 12



FIG. 13- ADJUSTING SPRING LOADED HINGE
  • Adjust the Spring Loaded Hinge on the Carriage Gate as shown in Fig. 13, this allows the gate to self-close against the Interlock.
  • Use a 5/32" Allen Key to release the tension on the loaded spring (turn clock wise)
  • Remove the set pin from the hinge
  • Increase tension (clock wise) or decrease tension (counter clock wise) and reinsert the set pin
 
 
 
 


FIG. 14- FASTEN CABLE TO SAFETY PLATE USING STRAPS
  • Fasten the Carriage Gate Interlock Cable to the Safety Plate under the Toe Plate using the plastic Nylon Tie Straps provided as shown in Fig. 14



FIG. 15- DRILL THROUGH BOTH ANGLE EDGES TO FASTEN GATE TO THRESHOLD
  • Mount the Upper Gate to the threshold at the upper landing as in Fig.15
  • Drill through the 5" X 5" Angle on the Upper Gate frame at suitable locations to provide adequate mounting holes for the angle, lag bolt or screw into place. OR Use a Polyurethane Adhesive to mount the threshold to the upper landing



FIG. 16- USE ADHESIVE TO FASTEN GATE TO EXISTING STRUCTURE
  • Use a Polyurethane Adhesive to mount the Upper Gate Post uprights to the existing structure as in Fig. 16
  • When using the Polyurethane Adhesive adequate clamping and support must be in place until the adhesive sets properly (NOTE CLAMP IN FIG. 16)
 
 


FIG. 17- MOUNT LOWER CALL STATION
  • Mount the Lower Remote Call Station in a suitable location as in Fig. 17
  • Run electrical conduit from the call station to the Outside Junction Box as well as from the Upper Gate to the Outside Junction Box located on the bottom left side of the Trust-T-Lift tower
  • Run the cables from the Call Station and Upper Gate through the conduit to the Outside Junction Box



FIG. 18- WIRING OUTSIDE JUNCTION BOX
  • The wires from the call station and Upper Gate and/or Interlocks are labeled with numbers that match the labels on the wires in the Outside Junction Box. The Outside Junction box is located at the bottom left side of the tower. Use the wire marrets provided to make the connections as in Fig. 18. (Unplug unit from power source before wiring)
  • Plug the unit in or hard wire it to an outlet providing 120 V.A.C. and 15 AMP protection



FIG. 19- INTERLOCKS MUST BE LOCKED FOR LIFT TO RUN PROPERLY
  • The Interlocks (both on the carriage and the upper gate) should be in the "Locked" Position as in Fig. 19 for the Trust-T-Lift unit to run.
 


FIG. 20- TIGHTEN LOWER MECHANICAL STOPS
  • Run the lift up and adjust the Lower Mechanical Stops so the lift stops at the bottom by breaking the Lower Limit circuit as apposed to activating the Safety Plate circuit, once adjusted use the jam nuts to lock them into place as in Fig. 20.

  • The electrical limit switch stop for the upper landing is controlled by adjusting the Upper Limit Adjusting Bracket as described in the Trust-T-Lift Installation Manual on page 2-7 Fig.17



FIG. 21- MOUNT TOWER TO EXISTING STRUCTURE
  • Mount the tower to the existing structure as in Fig. 21. Instructions are included with the tower-mounting angle



FIG. 22- INSTALL FRONT PANEL
  • Reinstall the Front panel into the Trust-T-Lift Unit as in Fig. 22

 

 

   