Commercial Wheelchair Lift
 |
Planet mobility wheelchair lifts allow people
with mobility issues to remain active, improving the quality of life. It's
there
personal freedom, and that is important to us… That is our job.
Safety, comfort and convenience were Planet
Mobility's #1 design
considerations.
Features
-
Innovative Soft Touch Control Pads for ease of operation.
-
Direct drive Worm-Gear / Screw-Nut Drive for maintenance free
operation, incorporating zero load start for cold weather climates
(drive system allows motor to get up to full speed before lifting
car).
-
Expanded Metal Platform allows full under platform visibility.
-
Keyed Emergency Stop to control use of lift.
Smooth and quiet performance makes this light weight,
dependable and versatile unit perfect for any residential or commercial
application.
Our High Tower Lift's
will go as high as 12' Feet and can be used with many
applications.
"Straight Trough":
Straight through application means that the lift would be entered by one
side and after raising and reaching the destination landing would be
exited on the opposite side.
"Adjacent Access":
Adjacent access application means that the lift would be entered by one
side and after raising and reaching the destination landing would be
exited to the right or left.
"Same Side": Same side
application means
that the lift would be entered by one side and after raising and
reaching the destination landing would be exited at the same location it
was entered.
Design Your Lift Here!
|
|
 |
Technical Specifications
 |
|
|
Adjacent Access
|
 |
|
Straight Through Access
|
|
Deck Dimensions (L, D, W)
|
Access
|
L
Deck Length
|
D
Deck Width
|
W
Total Width
|
|
Straight Through Access
|
54" (1372 mm)
|
34" (864 mm)
|
48" (1219 mm)
|
|
Adjacent Access
|
54" (1372 mm)
|
40" (1016 mm)
|
54" (1372 mm)
|
Tower Dimensions (H)
|
Total Travel
|
H
Tower Height
|
|
28" (711 mm) Lift Height
|
48" (1219 mm)
|
|
52" (1321 mm) Lift Height
|
72" (1829 mm)
|
|
72" (1829 mm) Lift Height
|
92" (2337 mm)
|
|
96" (2438 mm) Lift Height
|
118" (2997 mm)
|
|
120" (3048 mm) Lift Height
|
142" (3607 mm)
|
|
144" (3658 mm) Lift Height
|
166" (4216 mm)
|
Technical
- Constant pressure Soft
Touch control pads
- 550 pound (250-kg) lift
capacity
- Constant pressure Soft
Touch control pads
- 8 feet/minute lift speed
- Direct worm gear/acme
screw drive
- Non-load-bearing backup
safety nut on lift shaft
- Low maintenance
- Expanded metal platform
with full under platform visibility and non skid surface
|
- 8" positive action,
reversible toe-plate for universal access
- Emergency manual
operation
- Fuse box accessible from
carriage
- Quick and easy set-up and
adjustment
- Baked on Powder Coat
finish
- Baked on Powder Coat
finish
- Extreme Weather resistant
design
- U.L. and C.S.A. Certified
|
Options
- Under platform safety
plate and solid platform
- Carriage gate
- Landing gates
- Portable model
- Solid Hand Rail
- 12V DC battery backup
- 18" extra wide toe plate
- Remote call stations
- Electric Interlocks
|
|
View
Drawing Spec Sheet #1 |
|
|
View
Drawing Spec Sheet #2 |
|
|
-- |
|
|
Commercial Trust-T-Lift Installation Instructions
|
|
| The Commercial Trust-T-Lift is
pre-assembled and tested in the factory before shipping. The lift
is then disassembled into the components shown in Figure 1. All
fasteners required to assemble the lift are re-installed in their
respective positions after disassembly, except for the Lower
Mechanical Stops (5/8" X 3" Carriage Bolts) included
with the small parts bag. |
| Assembly of the Commercial unit is
as follows: |
|
 |
Straight or Adjacent Access
Unit
- Carefully unpackage the Commercial
Trust-T-Lift components, confirm the following parts as shown
in Fig. 1 are included:
|
| |
o Trust-T-Lift Tower |
Part A |
| o Carriage with Toe
Plate |
Part B |
| o Base Frame |
Part C |
| o Solid Handrail |
Part D |
| o Control Wall Extension |
Part E |
| o Carriage Gate |
Part F |
| o Upper Gate |
Part G |
| o Lower Remote Call
Station |
Part H |
| o Tower Mounting Angle |
Part I |
| FIG. 1- PARTS INCLUDED WITH A
STRAIGHT COMMERCIAL UNIT |
Adjacent Unit will also include a
corner post (not shown) |

FIG. 2- PLUGGING IN UNDER DECK SAFETY LIMITS |
- Install the base frame, tower and
carriage according to the Trust-T-Lift Installation Manual
Pages 1-1 to 2-3, in order to operate the lift without field
wiring completed, use a 12" insulated jumper wire and
bypass from #1 to #5 for down movement and from #1 to #2 for
up movement. Use extreme caution
when running the unit down as the lower limit switch is
bypassed and the drive nuts could possibly run out of the
guide channel
- Plug the Under Deck
Safety Limits into the Inside Junction Box as shown in Fig. 2.
- From this point
forward in order to run the unit without the field wiring
completed, only bypass #1 to #2 on the terminal strip (do
not hardwire the jumper wire in place, only bypass when
movement is required)
|

FIG. 3- REMOVE FRONT PANEL |
- Remove the front panel from the Trust-T-Lift
Unit as shown in Fig. 3.
|

FIG. 4- INSTALLING LOWER MECHANICAL STOPS |
- Insert the (2X) 5/8"X3" Carriage
Bolts and 5/8" Jam Nuts into the Lower Mechanical Stop
brackets on the underside of the guide frame as shown in Fig.
4. Thread the bolts into the Mechanical stops about ½",
they will be adjusted and jammed into place towards the end on
the installation.
|

FIG. 5A- INSTALLING CONTROL WALL EXTENSION |
- Mount the Control Wall Extension to the
Guide Frame as shown in Fig. 5A/5B.
- Fasteners- (6X) 10/32 X ½" Flathead
screws with (6X) Chrome Finishing Washers

FIG. 5B- FASTENING CONTROL WALL EXTENSION TO
GUIDE FRAME |

FIG. 6A- LOWER THE HANDRAIL INTO PLACE |
- For a Straight Access
Unit Mount the Solid Handrail to the Carriage as shown in Fig.
6A/6B
- Fasteners- (4X) 5/16 X
1¾" Bolts, (8X) 5/16 Washers, (4X) 5/16 Locknuts)
- For an Adjacent Access
Unit Mount the Solid Handrail to the Carriage as shown in Fig.
7A/7B, the safety pan must be lowered to access the mounting
holes. After mounting the Solid Handrail attach it to the
Control Wall Extension using small 1" Angle, remount
safety pan to finish
- Fasteners- (3X) 3/8 X
1¼" Bolts, (3X) 3/8" Locknuts, (2X) 10/32 X ½"
Screws
|

FIG. 8- MOUNTING GATE TO CONTROL WALL
EXTENSION |
- Mount the Carriage
Gate to the Control Wall Extension as shown in Fig. 8.
- Fasteners- (8X) 12/24
X ½" Flathead Screws
|

FIG. 9- MOUNT CORNER POST FOR ADJACENT UNIT |
- On Adjacent Units
mount the corner post as shown in Fig. 9. Square it to
Carriage Gate, if necessary shim with washers provided
|

FIG. 10- RUN CABLE UNDER TOE PLATE |
- Run Interlock cable
under the toe plate as in Fig. 10
|

FIG. 11- MOUNT INTERLOCK TO SOLID HANDRAIL |
- Mount the Carriage Gate Interlock to the Solid Hand Rail for
a Straight Unit and to the Corner Post for an Adjacent Unit as
shown in Fig. 11
- Fasteners- (2X) 10/32 X 1½" Screws
|

FIG. 12- ADJUST INTERLOCK KEY TAB IF
NECESSARY |
- Adjustment of the Interlock Key Tab may be necessary to
allow proper alignment, loosen the (2X) 10/32 X ½"
screws mounting it to the Aluminum Gate Tab and adjust as
necessary as shown in Fig. 12
|

FIG. 13- ADJUSTING SPRING LOADED HINGE |
- Adjust the Spring Loaded Hinge on the Carriage Gate as shown
in Fig. 13, this allows the gate to self-close against the
Interlock.
- Use a 5/32" Allen Key to release the tension on the
loaded spring (turn clock wise)
- Remove the set pin from the hinge
- Increase tension (clock wise) or decrease tension (counter
clock wise) and reinsert the set pin
|

FIG. 14- FASTEN CABLE TO SAFETY PLATE USING
STRAPS |
- Fasten the Carriage Gate Interlock Cable to the Safety Plate
under the Toe Plate using the plastic Nylon Tie Straps
provided as shown in Fig. 14
|

FIG. 15- DRILL THROUGH BOTH ANGLE EDGES TO
FASTEN GATE TO THRESHOLD |
- Mount the Upper Gate to the threshold at the upper landing
as in Fig.15
- Drill through the 5" X 5" Angle on the Upper Gate
frame at suitable locations to provide adequate mounting holes
for the angle, lag bolt or screw into place. OR Use a
Polyurethane Adhesive to mount the threshold to the upper
landing
|

FIG. 16- USE ADHESIVE TO FASTEN GATE TO
EXISTING STRUCTURE |
- Use a Polyurethane Adhesive to mount the Upper Gate Post
uprights to the existing structure as in Fig. 16
- When using the Polyurethane Adhesive adequate clamping
and support must be in place until the adhesive sets properly (NOTE
CLAMP IN FIG. 16)
|

FIG. 17- MOUNT LOWER CALL STATION |
- Mount the Lower Remote Call Station in a suitable location
as in Fig. 17
- Run electrical conduit from the call station to the Outside
Junction Box as well as from the Upper Gate to the Outside
Junction Box located on the bottom left side of the
Trust-T-Lift tower
- Run the cables from the Call Station and Upper Gate through
the conduit to the Outside Junction Box
|

FIG. 18- WIRING OUTSIDE JUNCTION BOX |
- The wires from the call station and Upper Gate and/or
Interlocks are labeled with numbers that match the labels on
the wires in the Outside Junction Box. The Outside Junction
box is located at the bottom left side of the tower. Use the
wire marrets provided to make the connections as in Fig. 18. (Unplug
unit from power source before wiring)
- Plug the unit in or hard wire it to an outlet providing 120
V.A.C. and 15 AMP protection
|

FIG. 19- INTERLOCKS MUST BE LOCKED FOR LIFT
TO RUN PROPERLY |
- The Interlocks (both on the carriage and the upper gate)
should be in the "Locked" Position as in Fig. 19 for
the Trust-T-Lift unit to run.
|

FIG. 20- TIGHTEN LOWER MECHANICAL STOPS |
- Run the lift up and adjust the Lower Mechanical Stops so the
lift stops at the bottom by breaking the Lower Limit circuit
as apposed to activating the Safety Plate circuit, once
adjusted use the jam nuts to lock them into place as in Fig.
20.
- The electrical limit switch stop for the upper landing is
controlled by adjusting the Upper Limit Adjusting Bracket as
described in the Trust-T-Lift Installation Manual on page
2-7 Fig.17
|

FIG. 21- MOUNT TOWER TO EXISTING STRUCTURE |
- Mount the tower to the existing structure as in Fig. 21.
Instructions are included with the tower-mounting angle
|

FIG. 22- INSTALL FRONT PANEL |
- Reinstall the Front panel into the Trust-T-Lift Unit as in
Fig. 22
|
Commercial Lift -
High Tower Lift -
Portable Lift -
Residential Lift -
Pricing
-
Photos
Design Your Lift Here! -
Porch Wheelchair Lift.....!
View Drawings And Pricing Here.........!

Planet Mobility Main Menu.!